Images are for illustration; refer to the table for dimensions.
Polyamide & Plastic Conduits
Plastic Spiral Conduit with Guide Wire
Black plastic spiral conduit supplied with a guide wire; it bends without elbows. 320 N light and 750 N medium series, Ø14–32 mm.
- −15 °C / +60 °C
- Ø14–32 mm
- Classification 2331 (320 N light series) and 3331 (750 N medium series): compression resistance 320 N / 750 N, impact resistance 2 kg, operating temperature −15…+60 °C
- No elbows are needed at bends, which saves labour and time
Technical data
- Operating temperature
- −15 °C / +60 °C
- Material
- Plastic
- Size range
- Ø14–32 mm
About this product
Plastic spiral conduit with guide wire is black plastic conduit with a pulling wire inside, so the cable is easily drawn in after the conduit is laid. Being flexible, it needs no elbows at bends, which saves labour and time. It is made in a 320 N light and a 750 N medium series, from Ø14 to Ø32 mm, for use from −15 °C to +60 °C.
Size table
The + button at the start of a row adds that size to your quote list. You set the quantity on the quote page.
320 N light series6 sizes
| Item code | Nominal size | Inner dia. (mm) | Outer dia. (mm) | Coil (m) |
|---|---|---|---|---|
| FLX-DSPRHS14-07 | 14 | 14 | 18.1 | 100 |
| FLX-DSPRHS16-07 | 16 | 16 | 19.8 | 100 |
| FLX-DSPRHS18-07 | 18 | 18 | 22.1 | 50 |
| FLX-DSPRHS20-07 | 20 | 20 | 24.2 | 50 |
| FLX-DSPRHS25-07 | 25 | 25 | 28.9 | 50 |
| FLX-DSPRHS32-07 | 32 | 32 | 36 | 50 |
750 N medium series6 sizes
| Item code | Nominal size | Inner dia. (mm) | Outer dia. (mm) | Coil (m) |
|---|---|---|---|---|
| FLX-DSPROS14-08 | 14 | 14 | 18 | 100 |
| FLX-DSPROS16-08 | 16 | 16 | 19.6 | 100 |
| FLX-DSPROS18-08 | 18 | 18 | 21.8 | 50 |
| FLX-DSPROS20-08 | 20 | 20 | 23.8 | 50 |
| FLX-DSPROS25-08 | 25 | 25 | 28.4 | 50 |
| FLX-DSPROS32-08 | 32 | 32 | 35.6 | 50 |
Sizes are taken from the 2026 product catalogue. Contact us for current stock and custom sizes.
Frequently asked questions
What is conduit with a guide wire for?
Conduit with a guide wire has a pulling wire fitted at the factory: once the conduit is laid, the cable is tied to the wire and pulled through as the wire is drawn out. It makes pulling cables easier on long runs with many bends. Our galvanized steel, PVC-coated steel and plastic conduits come in guide-wire types.
From the same group

- IP66–IP68
- LSZH

- IP66–IP68
- LSZH


- IP66–IP68

- IP67
- LSZH
Polyamide Conduit Connectors & Accessories
65 sizesView

Let us choose the right conduit for your project together
Send us the item code, size and quantity, and we will prepare your quote.