A
- ABS
- ABS (acrylonitrile butadiene styrene) is a tough, rigid, light thermoplastic widely used for electrical boxes and enclosures. Our ABS junction boxes have an unbreakable body, are rated IP65 and are used from −40 °C to +80 °C; our ABS enclosures come with opaque or transparent covers.
- Related products:ABS EnclosureABS Junction Box
- AISI 304 and 316L stainless steel
- AISI 304 and 316L are the two most widely used austenitic stainless steel grades. Thanks to the molybdenum in its alloy, 316L resists chlorides, sea air and chemicals better than 304; the L stands for low carbon. Our stainless steel conduits are made in both grades and work from −100 °C to +600 °C.
- Related products:Stainless Steel Flexible ConduitStainless-Braided Galvanized Steel ConduitStainless Steel Cable Ties
B
- Bending radius
- The bending radius is the smallest radius to which a conduit can be bent without being crushed, narrowing its section or harming the cable inside. A small radius makes installation easier in tight spaces and inside machines. On our polyamide conduits it runs from 15 mm to 90 mm depending on size; our steel conduits also bend to a very small radius.
- Related products:Polyamide (PA6) Corrugated ConduitGalvanized Steel Flexible Conduit
- Bushing
- A bushing is a ring-shaped part fitted to the end of a conduit that protects the cable sheath from the conduit's sharp edge; it may be plastic or metal. An insulated grounding bushing also bonds the metal conduit to the earthing conductor. An end cap is a similar protector that closes off the conduit end.
- Related products:Conduit Bushings & Locknuts
C
- Clamping range
- The clamping range is the smallest and largest cable outer diameter a cable gland can seal and hold; our M20 metal cable gland, for example, comes in a 4–10 mm and a 6–12 mm type. The gland is chosen so that the cable's outer diameter falls inside this range; if it is very close to a limit, the next size up or down is safer. For clamps, the same term means the range of diameters a clamp can tighten.
- Related products:Metal Cable GlandPolyamide Cable GlandHeavy-Duty Hose Clamps
- Compression strength
- Compression strength is the load a conduit carries without being crushed, given in newtons (N); in EN 61386 the light series is 320 N and the medium series 750 N. The medium series is usually chosen where loads are high, as in concrete pours and under plaster, and the light series where stress is low. Our plastic spiral conduit is rated 350 N and our PVC corrugated conduit 450 N.
- Related products:Plastic Spiral ConduitPE & Halogen-Free Coil PipesPlastic Spiral Conduit with Guide Wire
- Conduit body
- A conduit body is a cast fitting with a removable cover that makes a turn, a branch or a pull point in a threaded conduit run. The letters show where the outlet is: LB turns 90° out of the back, LL to the left and LR to the right; C is a straight pull point and T a branch. Our conduit bodies are cast aluminium, from 1/2" to 2".
- Related products:Threaded Aluminium Conduit Bodies
E
- Electromagnetic interference (EMI)
- Electromagnetic interference (EMI) is electrical noise from motors, drives and power cables that couples into nearby signal and control cables and causes faults or false readings. The metal braid of a steel-braided conduit forms a screen around the cable and gives very high shielding against it.
- Related products:Steel-Braided Galvanized ConduitStainless-Braided Galvanized Steel ConduitPVC-Jacketed Steel-Braided ConduitLiquid-Tight Steel-Braided Conduit
- EMT
- EMT (electrical metallic tubing) is thin-wall, threadless steel conduit for electrical installations: its ends are not threaded but joined with screw-type or compression couplings and connectors, and it is bent to change direction. It is a North American system used for installations inside buildings. Our EMT has a pre-galvanized coating and is made to ANSI C80.3 from 1/2" to 2".
- Related products:EMT Threadless Galvanized Steel ConduitEMT Couplings, Elbows & Connectors
- EN 61386 and the classification code
- EN 61386 is the European standard for conduit systems for cable management; it classifies conduits by compression and impact strength and by temperature range. Its four-digit classification code gives, in order, compression, impact, lowest and highest temperature: 2331 on the plastic conduit with guide wire means 320 N, a 2 kg impact and −15 °C to +60 °C. Our PVC corrugated conduit is made to this standard.
- Related products:PVC Corrugated ConduitPlastic Spiral Conduit with Guide Wire
- EPDM
- EPDM (ethylene propylene diene monomer) is a synthetic rubber that resists weathering, ozone and UV and stays flexible over a wide temperature range. In our rubber-lined connection clamps the lining around the pipe is EPDM, forming a flexible cushion between pipe and clamp.
- Related products:Rubber-Lined Connection Clamps
- Ex d (flameproof enclosure)
- Ex d is a type of protection for explosive atmospheres (EN 60079-1): an explosion that may occur inside the enclosure is contained within it, and the flame paths stop it from igniting the gas outside. An Ex d cable gland keeps this flameproof integrity at the cable entry; our Ex cable glands come in Ex d types.
- Related products:Ex Cable Glands
- Ex e (increased safety)
- Ex e is a type of protection for explosive atmospheres (EN 60079-7): additional measures prevent arcs, sparks and dangerous hot surfaces in normal operation. An Ex e cable gland keeps the ingress protection and integrity of an Ex e enclosure at the cable entry; our Ex cable glands come in Ex e types.
- Related products:Ex Cable Glands
G
- Galvanizing
- Galvanizing is coating steel with zinc against corrosion; the zinc layer keeps moisture and oxygen from the steel and goes on protecting it even where it is scratched. In pre-galvanizing the strip or sheet is coated before it is formed; in hot-dip galvanizing the finished part is dipped in molten zinc. Galvanized flexible steel conduits work from −50 °C to +300 °C.
- Related products:Galvanized Steel Flexible ConduitEMT Threadless Galvanized Steel Conduit
- Gas groups (IIA, IIB, IIC)
- Gas groups sort explosive gases by how easily they ignite: IIA (propane, for example), IIB (ethylene, for example) and the most demanding, IIC (hydrogen, acetylene). A product suitable for IIC can also be used in IIB and IIA atmospheres. Our Ex cable glands are for gas groups IIA, IIB and IIC.
- Related products:Ex Cable Glands
- GAS thread (BSP)
- GAS thread is the name used in Turkey for British Standard Pipe (BSP) threads: a 55° Whitworth profile named in inches, like 1/2". It is common on service pipes and fittings; although its sizes resemble NPT, the angle and profile differ, so the two do not fit each other. The Compression (Silok) Conduit Gland comes with GAS threads from 1/4" to 3".
- Related products:Compression (Silok) Conduit Gland
- Glow-wire test
- The glow-wire test (IEC 60695-2-11) checks how a plastic withstands the overheating an electrical fault can cause: a wire heated to a set temperature is pressed onto the sample, which must not ignite, or must go out shortly after the wire is withdrawn. Our standard ABS junction boxes pass the test at 650 °C and the HF type at 960 °C.
- Related products:ABS Junction BoxSealed Junction Boxes (Mini)
- Guide wire
- A guide wire is a pulling wire supplied ready inside the conduit: once the conduit is laid, the cable is tied to the wire and pulled through as the wire is drawn out. On long runs with many bends there is no need to push a fish tape through first; we make steel, PVC-coated and plastic conduits with a guide wire.
- Related products:Steel Conduit with Guide WirePVC-Coated Steel Conduit with Guide WirePlastic Spiral Conduit with Guide Wire
H
- Halogen-free (LSZH)
- LSZH (low smoke zero halogen) describes materials that give off little smoke in a fire and contain no halogens such as chlorine or bromine. Halogenated materials like PVC give off dense smoke and corrosive gas when they burn; a halogen-free coating affects visibility on escape routes and equipment less in crowded indoor spaces. The coated and liquid-tight series come in halogen-free versions.
- Related products:Halogen-Free (LSZH) Coated Galvanized Steel ConduitLiquid-Tight Halogen-Free Jacketed Steel ConduitHalogen-Free Flush-Mounting Boxes
- Hazardous area zone
- A zone classifies a hazardous area by how often an explosive atmosphere may form there. Gas areas are Zones 0, 1 and 2, dust areas Zones 20, 21 and 22: in Zones 1 and 21 an explosive atmosphere may form occasionally in normal operation; in Zones 2 and 22 it is not expected and, if it forms, lasts only briefly. Our Ex cable glands are for Zones 1, 2, 21 and 22.
- Related products:Ex Cable Glands
I
- IK code
- The IK code is a rating defined in IEC 62262 for how well a housing withstands mechanical impact; it runs from IK00 to IK10, each step standing for a given impact energy. IK06, for example, withstands 1 joule and IK08 5 joules; our sealed mini junction boxes are IK08.
- Related products:Sealed Junction Boxes (Mini)Rigid PVC Conduit
- IMC and RSC
- IMC (intermediate metal conduit) and RSC (rigid steel conduit) are heavy-wall steel conduits joined by threading their ends into couplings. RSC has the thickest wall; IMC is thinner and lighter but still threaded. They are used instead of EMT where mechanical stress is high, with conduit bodies at turns and pull points.
- Related products:IMC & RSC Steel ConduitThreaded Aluminium Conduit Bodies
- IP code
- The IP code is a two-digit rating defined in IEC 60529 that shows how well a product is protected against solid objects, dust and water. The first digit (0–6) is protection against solids and dust, the second (0–9) against water; the higher the digit, the better the protection. A run is only as well protected as its weakest part, conduit or fitting.
- Related products:Liquid-Tight PVC-Jacketed Steel ConduitMetal Cable Gland
- IP40
- IP40 means protected against solid objects larger than 1 mm and not protected against water. Uncoated flexible steel conduits and uncoated braided conduits are IP40: they protect cables from crushing and cuts but do not keep water out. In wet places a coated or liquid-tight type is chosen.
- Related products:Galvanized Steel Flexible ConduitSteel-Braided Galvanized Conduit
- IP54
- IP54 means dust-protected and protected against water splashing from any direction; dust is not fully kept out but cannot enter in harmful amounts. PVC-coated steel conduits start at IP54; the Steel Conduit Fitting and the PVC-jacketed braided conduit are IP54.
- Related products:PVC-Coated Galvanized Steel ConduitSteel Conduit FittingPVC-Jacketed Steel-Braided Conduit
- IP65
- IP65 means dust-tight and protected against water jets from any direction. It is a common rating for boxes in places that are hosed down or splashed; the ABS junction boxes and the Acqua series distribution boards are IP65.
- Related products:ABS Junction BoxIP65 Distribution Boards (Acqua Series)
- IP66
- IP66 means dust-tight and protected against powerful water jets, stronger than those of IP65. The halogen-free coated conduit reaches IP66 and the Liquid-Tight Steel-Braided Conduit is rated IP66; polyamide and PVC corrugated conduits are rated IP66–IP68.
- Related products:Liquid-Tight Steel-Braided ConduitHalogen-Free (LSZH) Coated Galvanized Steel Conduit
- IP67
- IP67 means dust-tight and protected against temporary immersion: in the standard test the product stays under 1 metre of water for 30 minutes. The Liquid-Tight Conduit Fitting, the Compression (Silok) Conduit Gland and polyamide conduit connectors with a suitable gasket are IP67.
- Related products:Liquid-Tight Conduit FittingCompression (Silok) Conduit GlandPolyamide Conduit Connectors & Accessories
- IP68
- IP68 means dust-tight and protected against continuous immersion; the depth and duration are more severe than for IP67 and are set by the conditions the manufacturer states. Metal and polyamide cable glands are IP68; liquid-tight PVC-jacketed conduit and polyamide and PVC corrugated conduits give protection up to IP68.
- Related products:Metal Cable GlandPolyamide Cable GlandLiquid-Tight PVC-Jacketed Steel ConduitPolyamide (PA6) Corrugated Conduit
- IP69
- IP69 means dust-tight and protected against high-pressure, high-temperature water jets; it is defined for places that are often cleaned by pressure washing. The Liquid-Tight Halogen-Free Jacketed Steel Conduit gives protection up to IP69.
- Related products:Liquid-Tight Halogen-Free Jacketed Steel Conduit
M
- Metric thread
- A metric thread is the 60° ISO thread profile; on cable glands it is used with a fine pitch and written like M20×1.5, where the number after M is the outer diameter in millimetres and the second number the pitch. Our cable glands run from M12×1.5 to M63×1.5, and the Ex glands up to M90×2.0. It is the standard choice for new enclosure and machine designs.
- Related products:Metal Cable GlandPolyamide Cable GlandPolyamide Lock Nut
N
- NBR (nitrile rubber)
- NBR (nitrile rubber) is a synthetic rubber that resists oil, fuel and many chemicals; it is used for O-rings and seals in fittings. The O-rings of our steel and liquid-tight conduit fittings are NBR; in our Ex glands, NBR seals are used from −30 °C to +120 °C.
- Related products:Steel Conduit FittingLiquid-Tight Conduit FittingEx Cable Glands
- Nickel-plated brass
- Brass is an easily machined alloy of copper and zinc; nickel plating protects its surface from corrosion and gives it a bright finish. The bodies of our steel and liquid-tight conduit fittings and of our metal cable glands are nickel-plated brass. MS58, used for our Ex glands, is a free-machining brass grade.
- Related products:Metal Cable GlandSteel Conduit FittingEx Cable Glands
- NPT thread
- NPT (National Pipe Taper) is a tapered pipe thread of US origin: it has a 60° angle, is named in inches, and seals as the tapered threads wedge together on tightening, usually with a sealing tape or paste. It is common in plants built to North American standards. The Steel Conduit Fitting, the Compression (Silok) Conduit Gland and our Ex cable glands come with NPT threads.
- Related products:Steel Conduit FittingCompression (Silok) Conduit GlandEx Cable Glands
- NW (nominal width)
- NW (Nennweite) is the nominal width of a polyamide corrugated conduit size and roughly matches its inner diameter. Our NW 17 polyamide conduit, for example, has a 16.8 mm inner and 21.4 mm outer diameter. Our polyamide conduits are made in 13 sizes from NW 6.5 to NW 48.
- Related products:Polyamide (PA6) Corrugated ConduitSplit Polyamide Corrugated Conduit
P
- PE (polyethylene)
- PE (polyethylene) is a flexible plastic that resists impact and moisture; it is used for smooth-walled coil pipes. Because it comes in long coils, a run has few joints and is easily laid under plaster, in concrete or in drywall. Our polyethylene coil pipes are black and made in the 320 N light series.
- Related products:PE & Halogen-Free Coil Pipes
- PG thread
- PG (Panzergewinde) is an older thread standard of German origin (DIN 40430) with an 80° rounded profile and a pitch that varies with size, named from Pg 7 to Pg 48. It is still common on existing enclosures but has given way to metric threads in new designs. It does not fit a metric thread; our cable glands and polyamide connectors are made in both.
- Related products:Metal Cable GlandPolyamide Cable GlandPolyamide Conduit Connectors & Accessories
- Polyamide (PA6, PA 6.6)
- Polyamide (nylon) is a tough, flexible, halogen-free engineering plastic. PA6 (polyamide 6) is the material of our corrugated conduits, connectors, cable glands and lock nuts; PA 6.6 is used for cable ties for its higher strength. Polyamide conduit works from −40 °C to +120 °C.
- Related products:Polyamide (PA6) Corrugated ConduitPolyamide Cable GlandStandard Cable Ties (Polyamide 6.6)
- PVC
- PVC (polyvinyl chloride) is the most common plastic in electrical installations: easy to process, resistant to moisture and oil, and non-conductive. It contains chlorine, so it is halogenated and gives off dense smoke and corrosive gas in a fire; that is why halogen-free (LSZH) material is preferred in crowded indoor spaces. We use PVC for coatings, jackets, corrugated conduit, cable trunking and rigid conduit.
- Related products:PVC Corrugated ConduitRigid PVC ConduitPVC Cable Trunking
R
- RAL colour code
- RAL is a colour standard of German origin; each colour has a four-digit code, so products from different makers match in shade. Our polyamide conduits, for example, are grey RAL 7031 and black RAL 9011, and our ABS junction boxes light grey RAL 7035. Our cable glands are made in RAL 7001, 7035 and 9005.
- Related products:Polyamide (PA6) Corrugated ConduitPolyamide Cable GlandABS Junction Box
S
- Self-extinguishing
- A self-extinguishing material does not keep burning once the flame source is removed but goes out by itself, which limits how far a fire can travel along a cable run. Our polyamide conduits and our halogen-free coated and liquid-tight conduits are self-extinguishing.
- Related products:Polyamide (PA6) Corrugated ConduitHalogen-Free (LSZH) Coated Galvanized Steel ConduitLiquid-Tight PVC-Jacketed Steel Conduit
- Square-lock profile
- A square-lock profile is the structure of a flexible conduit made by winding steel strip in a helix and interlocking its edges. The interlocks give the conduit both flexibility and crush resistance; the light square-lock profile is what gives our steel conduits their small bending radius.
- Related products:Galvanized Steel Flexible ConduitStainless Steel Flexible Conduit
T
- Trade size
- The trade size is the name of a conduit size given in inches, like 1/2" or 3/4"; it is not equal to the actual inner or outer diameter. Our 1/2" galvanized steel conduit, for example, has a 16 mm inner and 20 mm outer diameter, while 1/2" EMT has a 15.8 mm inner and 17.93 mm outer diameter. That is why millimetre dimensions are compared when choosing conduit and fittings.
- Related products:Galvanized Steel Flexible ConduitEMT Threadless Galvanized Steel Conduit
- Tunnel formwork
- Tunnel formwork is a construction method in which walls and slabs are cast in reinforced concrete in one pour using steel forms; it is common in large housing projects. Because electrical boxes and conduits are placed in the formwork before the concrete is poured, they must withstand the pressure of the concrete and be fixed to the formwork. Our halogen-free flush-mounting boxes include types made for tunnel formwork.
- Related products:Halogen-Free Flush-Mounting Boxes
U
- UL94 flammability class
- UL94 is the standard that classifies how plastics behave in a flame. In class HB a horizontal sample burns slowly; in classes V2, V1 and V0 a vertical sample goes out within a set time once the flame is removed, V0 being the best (V2 allows burning drips). Rigid PVC conduit is V0, polyamide conduit V2 and PVC corrugated conduit HB.
- Related products:Rigid PVC ConduitPolyamide (PA6) Corrugated ConduitPVC Corrugated Conduit
Z
- Zamak
- Zamak is an alloy of zinc with aluminium, magnesium and copper, shaped by pressure die casting; it allows complex parts to be made accurately and in series. The screw-type couplings and connectors of our EMT range are zamak die castings.
- Related products:EMT Couplings, Elbows & Connectors
Let us choose the right conduit for your project together