Skip to content
Fleks
Liquid-Tight Steel-Braided Conduit

Images are for illustration; refer to the table for dimensions.

Liquid-Tight & Braided Conduits

Liquid-Tight Steel-Braided Conduit

A liquid-tight PVC jacket and a steel braid together: IP66 protection, EMI shielding, −20 °C to +100 °C.

  • IP66
  • −20 °C / +100 °C
  • EMI
  • 1/4"–2"
  • CE
  • High impact strength
  • Self-extinguishing
  • High UV resistance (black)
  • High abrasion resistance

Technical data

Operating temperature
−20 °C / +100 °C
Protection rating
IP66
Material
Galvanized steel, liquid-tight PVC jacket, galvanized steel braid
Flexibility
Medium
EMI shielding
Very high
Liquid-tight
Yes
Size range
1/4"–2"
Certificates
CE

About this product

Liquid-tight steel-braided conduit brings a liquid-tight PVC jacket and a steel braid together: IP66 protection, EMI shielding, and high impact and abrasion resistance. Its black jacket gives high UV resistance, and it is self-extinguishing. It works from −20 °C to +100 °C, is made in 8 sizes from 1/4" to 2" and connects with the Liquid-Tight Conduit Fitting.

Size table

The + button at the start of a row adds that size to your quote list. You set the quantity on the quote page.

Liquid-Tight Steel-Braided Conduit: size table
Item codeNominal sizeTrade sizeInner dia. (mm)Outer dia. (mm)Coil (m)
F.07.2010101/4"10.51830
F.07.2012123/8"12.72030
F.07.2016161/2"16.323.430
F.07.2021213/4"21.328.530
F.07.2027271"2735.330
F.07.2035351 1/4"35.54415
F.07.2040401 1/2"40.550.215
F.07.2051512"516515

Sizes are taken from the 2026 product catalogue. Contact us for current stock and custom sizes.

Technical drawing

  • Liquid-Tight Steel-Braided Conduit: Technical drawing

Frequently asked questions

When should braided conduit be chosen?

Steel-braided conduit is chosen when cables need protection against electromagnetic interference (EMI) as well as mechanical damage, for example where signal and control cables run close to drive and motor cables. The braid forms a screen over the galvanized core and gives very high shielding. Where water and dust are present too, the Liquid-Tight Steel-Braided Conduit adds IP66 protection.

From the same group

Articles about this product

  • Guide3 min read

    Liquid-tight conduit: where and why it is used

    Liquid-tight conduit is galvanized flexible steel conduit enclosed in a thick PVC or halogen-free jacket, rated IP66–IP69. It is used wherever cables meet water, dust, petrol or solvents.

  • Guide4 min read

    How to choose a flexible steel conduit

    Four questions decide the right flexible steel conduit: ambient temperature, exposure to water and dust, electromagnetic interference, and cable size. Temperature picks the material, sealing picks the coating, interference picks the braid, and the cable bundle picks the diameter.

Let us choose the right conduit for your project together

Send us the item code, size and quantity, and we will prepare your quote.