Guide · 4 min read
Cable glands explained: what they do and how to choose
Fleks Elektrik Technical Team
In short
A cable gland is the fitting that keeps water and dust out where a cable enters an enclosure or device and anchors the cable against pulling. The right gland is chosen by four things: the cable's outer diameter, the thread type, the thread length and the environment.
What does a cable gland do?
When a cable enters an enclosure, a junction box or a motor housing, a gap is left around the entry. A cable gland closes that gap and does three jobs: it keeps water and dust out, anchors the cable against pulling and vibration, and protects the cable sheath from the sharp edge of the hole. The terminals and connections inside are not strained, and the housing keeps its protection class.
The parts of a cable gland
- Body: the threaded part screwed into the enclosure (metric or PG).
- Clamping insert: presses the seal around the cable as the cap nut is tightened.
- Seal: seals around the cable.
- Cap nut: tightened to seat the insert and the seal on the cable.
- O-ring: seals between the body and the enclosure.
On our metal cable gland the body and cap nut are nickel-plated brass, the clamping insert PA6, the O-ring NBR and the seal TPV. On our polyamide cable gland the body and cap nut are PA6 and the seal TPV.
Metal or polyamide?
| Feature | Metal cable gland | Polyamide cable gland |
|---|---|---|
| Body | Nickel-plated brass | Polyamide (PA6) |
| Protection class | IP68 | IP68 |
| Operating temperature | −40 °C / +105 °C | −20 °C / +100 °C |
| Thread | Metric (M12–M63) and PG | Metric (M12–M63) and PG |
| Thread length | Standard and long | Standard and long |
| Colour | Metal | Grey, light grey, black |
| Halogens | — | Halogen-free |
Metal glands are preferred in machine and industrial applications where mechanical strength and a wide temperature range matter. Polyamide glands are light, halogen-free and come in colours that suit plastic enclosures; they are common in general enclosure and box work.
Four steps to the right gland
- Measure the cable's outer diameter. Choose the gland so that the diameter falls inside its clamping range; if it sits right at a limit, the next size up or down is safer.
- Decide the thread type. New enclosures take metric threads, existing enclosures with PG holes take PG; the two do not fit each other.
- Choose the thread length. A standard thread is enough for thin-walled enclosures; for a thick wall or a nut on the inside, take the long-thread type.
- Choose the material for the environment. Metal for high temperatures and mechanical stress, polyamide where lightness and halogen-free material are wanted; in explosive atmospheres an Ex gland is needed.
Example: our M20 metal cable glands
| Code | Thread | Clamping range | Thread length |
|---|---|---|---|
| F.11.1003 | M20×1.5 | 4–10 mm | 8 mm |
| F.11.1004 | M20×1.5 | 6–12 mm | 8 mm |
| F.11.2003 | M20×1.5 | 4–10 mm | 12 mm |
| F.11.2004 | M20×1.5 | 6–12 mm | 12 mm |
The same M20 thread comes with two clamping ranges: for an 8 mm cable both types fit, for an 11 mm cable only the 6–12 mm type. Each row's code is in the table on the product page; add it to your quote list to ask for it directly.
Lock nuts and blind plugs
A cable gland is fixed to the enclosure from the inside with a Polyamide Lock Nut; where the hole is not threaded, the nut is needed. Unused cable entries are closed with a Polyamide Blind Plug; a single open hole lowers the protection class of the whole box. Both are made of halogen-free PA6, with metric and PG threads, in grey and black.
Ex glands for explosive atmospheres
Standard glands are not used in hazardous areas where explosive gas or dust may be present. Our Ex cable glands have single compression for unarmoured cable; the Ex d and Ex e types are for Zones 1, 2, 21 and 22 and gas groups IIA, IIB and IIC. They are made in MS58 brass, stainless steel or aluminium, with metric and NPT threads from M12 to M90, and work from −60 °C to +180 °C depending on the seal material. For certificates and declarations of conformity, write to our sales team.
Common mistakes
- Choosing the gland by thread size alone without checking the cable diameter: the gland does not grip the cable and leaks.
- Forcing a metric gland into a PG hole, or the other way round: the thread is damaged.
- Overtightening the cap nut: the seal is crushed and the cable sheath damaged.
- Putting more than one cable through one gland: the standard seal is made for a single cable.
- Leaving spare entries open.
Just send us the cable's outer diameter and the size of the hole in the enclosure; our sales team will suggest the right gland, nut and plug with their item codes.
What cable size does an M20 gland take?
Our metal cable glands come in two M20 types: one takes cables of 4–10 mm outer diameter, the other 6–12 mm. Our polyamide cable glands have the same two clamping ranges for M20. If your cable falls within both ranges, choose the type in which it sits nearer the middle.
Which cable does a Pg 16 gland suit?
On our metal cable glands the Pg 16 thread is for cables of 10–14 mm outer diameter; in metric threads the same cable is taken by M25. Pg 13.5 comes in two types, for 4–10 and 6–12 mm.
How is a cable gland fitted?
Put the gland body through the hole in the enclosure and tighten it from the inside with a lock nut; if the hole is threaded, screw the body straight in. Then loosen the cap nut, pass the cable through the gland and, with the cable in place, tighten the cap; the clamping insert presses the seal around the cable. Do not overtighten: if the cable does not slip when pulled by hand, it is tight enough.
Related products

- IP68

- IP68
- LSZH

- LSZH
Polyamide Lock Nut
9 sizesView

- LSZH
Polyamide Blind Plug
10 sizesView

- IP66–IP68
More articles

Guide5 min read
Flexible steel conduit sizes: inch, ID and OD table
Flexible steel conduit is made in 18 sizes from 1/4" to 4" and is chosen by its inner diameter: 1/2" conduit, for example, is 16 mm inside and 20 mm outside. The inch value is a name; conduit, fittings and clamps are matched by their millimetre dimensions.

Guide4 min read
Polyamide vs PVC corrugated conduit: the difference
Polyamide corrugated conduit works from −40 °C to +120 °C, is halogen-free and self-extinguishing. PVC corrugated conduit works from −20 °C to +70 °C and is made for general-purpose installations. Polyamide is chosen where it is hot, where things move, or where halogen-free material is required.

Guide3 min read
Cable trunking or rigid PVC conduit? Types and sizes
Cable trunking is a profile with an opening cover, practical for surface runs and panel wiring where cables will be added later. Rigid PVC conduit carries cables in a closed tube and is made for surface and concealed installations. The choice depends on how much protection the cable needs and whether it will change.

Guide3 min read
What is EMT conduit? How it differs from other conduit
EMT (electrical metallic tubing) is thin-wall, threadless galvanized steel conduit for electrical installations inside buildings. Its ends are not threaded; it is joined with screw-type or compression couplings and bent to change direction.

Guide3 min read
How to connect flexible conduit to a fitting
Flexible conduit is connected to a fitting in four steps: choose the fitting, cut the conduit, seat it and tighten the cap, then fix the fitting with its nut. For a sealed run, conduit and fitting must share the same protection class.

Guide3 min read
Galvanized or stainless steel conduit? A comparison
Galvanized flexible steel conduit works from −50 °C to +300 °C and covers most general installations. Stainless steel conduit works from −100 °C to +600 °C and is made for corrosive environments. The choice comes down to temperature, chemicals and moisture.

Guide3 min read
PVC-coated vs halogen-free (LSZH) conduit
PVC-coated and halogen-free coated conduits protect the steel core from moisture, oil and dust in the same way; they differ in fire behaviour and temperature. A halogen-free (LSZH) coating gives off little smoke and no halogen gases in a fire, so it is chosen for crowded indoor spaces.

Guide3 min read
Liquid-tight conduit: where and why it is used
Liquid-tight conduit is galvanized flexible steel conduit enclosed in a thick PVC or halogen-free jacket, rated IP66–IP69. It is used wherever cables meet water, dust, petrol or solvents.

Guide4 min read
How to choose a flexible steel conduit
Four questions decide the right flexible steel conduit: ambient temperature, exposure to water and dust, electromagnetic interference, and cable size. Temperature picks the material, sealing picks the coating, interference picks the braid, and the cable bundle picks the diameter.

Technical3 min read
What does IP68 mean? IP ratings explained
In an IP code the first digit is protection against dust and solid objects, the second against water. IP68 means fully dust-tight and able to withstand continuous immersion.

Technical3 min read
PG vs metric gland threads: the difference and which to choose
PG and metric are two separate thread standards for cable glands, and they do not fit each other. New designs use metric threads; for existing enclosures with PG entries, choose a PG gland or an adapter.