Skip to content
Fleks

Technical · 3 min read

What does IP68 mean? IP ratings explained

Fleks Elektrik Technical Team

In short

In an IP code the first digit is protection against dust and solid objects, the second against water. IP68 means fully dust-tight and able to withstand continuous immersion.

How to read an IP code

The IP (Ingress Protection) code is defined in IEC 60529 and has two digits. The first is the degree of protection against solid objects and dust, the second against water; the higher the digit, the greater the protection. An X in place of a digit (IPX7, for example) means no rating has been given for that part.

First digitProtection against solids and dust
0No protection
1Objects larger than 50 mm (contact with a hand)
2Objects larger than 12.5 mm (a finger)
3Objects larger than 2.5 mm (tools, thick wire)
4Objects larger than 1 mm (thin wire, screws)
5Dust-protected: dust may enter, but not in harmful amounts
6Dust-tight
Second digitProtection against water
0No protection
1Vertically dripping water
2Dripping water when tilted by 15°
3Spraying water (up to 60°)
4Splashing water from any direction
5Water jets
6Powerful water jets
7Temporary immersion (1 m, 30 minutes)
8Continuous immersion (under conditions the manufacturer states)
9High-pressure, high-temperature water jets

The ratings people ask about most

  • IP54: dust-protected and resistant to splashing water; enough for indoor areas with moisture and oil.
  • IP65: dust-tight and resistant to water jets; common for boxes in places that are hosed down or splashed.
  • IP66: dust-tight and resistant to powerful water jets.
  • IP67: dust-tight; in the standard test it can stay under 1 metre of water for 30 minutes.
  • IP68: dust-tight; withstands longer and deeper immersion than IP67, under conditions the manufacturer states.
  • IP69: dust-tight; withstands washing with high-pressure hot water.

The difference between IP67 and IP68

Both are dust-tight; the difference is how long and how deep the product can stay under water. For IP67 the standard fixes the test: 1 metre for 30 minutes. For IP68 the conditions are more severe and are stated by the manufacturer, so when comparing two IP68 products, look at the manufacturer's conditions.

Protection against water jets (5 and 6) and against immersion (7 and 8) are separate tests. A product that withstands jets may not withstand immersion, and one that withstands immersion may not withstand powerful jets; that is why some products carry two ratings together, such as IP66/IP68.

What it means across the range

ProductProtection class
Uncoated flexible steel conduits (galvanized, stainless)IP40
Steel-braided galvanized and stainless conduitsIP40
PVC-jacketed steel-braided conduitIP54
PVC-coated flexible steel conduitIP54–IP65
Halogen-free coated flexible steel conduitIP54–IP66
Liquid-tight steel-braided conduitIP66
Liquid-tight PVC-jacketed conduitIP66–IP68
Liquid-tight halogen-free jacketed conduitIP66–IP69
Polyamide and PVC corrugated conduitsIP66–IP68
Steel conduit fittingIP54
Liquid-tight fitting, compression (Silok) glandIP67
Polyamide conduit connectors (with a suitable gasket)IP67
Metal and polyamide cable glandsIP68
Ex cable glandsIP66–IP68
ABS junction box, Acqua series distribution boardIP65
Sealed mini junction boxIP55

A run is only as well protected as its weakest link

An IP68 conduit connected with an IP54 fitting makes an IP54 run. In the same way, an enclosure fitted with an IP68 cable gland cannot be better protected than the enclosure itself. An unused cable entry left open loses the box its protection altogether; spare entries should be closed with blind plugs.

  • Define the environment: dust, splashing water, jets, immersion or pressure washing.
  • Choose conduit, fittings and boxes of the same class or higher.
  • Check that the fitting's seal and O-ring are in place and undamaged.
  • Choose the cable gland so that its clamping range takes the cable's outer diameter; a loose gland leaks.
  • Close spare entries with blind plugs.

The IP code covers protection against dust and water only. Impact resistance has its own rating, the IK code, and the fire behaviour of plastics is rated with the UL94 classes.

What is the difference between IP65 and IP67?

Both are dust-tight. IP65 withstands water jets but is not tested for immersion; IP67 withstands 30 minutes under 1 metre of water. Where water can collect or the product may be submerged, choose IP67 or IP68.

Is IP54 enough outdoors?

IP54 protects against splashing water, not against direct water jets or pressure washing. It may be enough outdoors under cover, but in the open and where things are washed down, IP65 or higher is preferred.

What does IP20 mean?

IP20 means protected against solid objects larger than 12.5 mm (a finger) and not protected against water; it is for dry indoor areas. Our cable reels are rated IP20; the FLX-MM German-type metal reel also comes with an IP44 option.

Related products

More articles

  • Guide5 min read

    Flexible steel conduit sizes: inch, ID and OD table

    Flexible steel conduit is made in 18 sizes from 1/4" to 4" and is chosen by its inner diameter: 1/2" conduit, for example, is 16 mm inside and 20 mm outside. The inch value is a name; conduit, fittings and clamps are matched by their millimetre dimensions.

  • Guide4 min read

    Cable glands explained: what they do and how to choose

    A cable gland is the fitting that keeps water and dust out where a cable enters an enclosure or device and anchors the cable against pulling. The right gland is chosen by four things: the cable's outer diameter, the thread type, the thread length and the environment.

  • Guide4 min read

    Polyamide vs PVC corrugated conduit: the difference

    Polyamide corrugated conduit works from −40 °C to +120 °C, is halogen-free and self-extinguishing. PVC corrugated conduit works from −20 °C to +70 °C and is made for general-purpose installations. Polyamide is chosen where it is hot, where things move, or where halogen-free material is required.

  • Guide3 min read

    Cable trunking or rigid PVC conduit? Types and sizes

    Cable trunking is a profile with an opening cover, practical for surface runs and panel wiring where cables will be added later. Rigid PVC conduit carries cables in a closed tube and is made for surface and concealed installations. The choice depends on how much protection the cable needs and whether it will change.

  • Guide3 min read

    What is EMT conduit? How it differs from other conduit

    EMT (electrical metallic tubing) is thin-wall, threadless galvanized steel conduit for electrical installations inside buildings. Its ends are not threaded; it is joined with screw-type or compression couplings and bent to change direction.

  • Guide3 min read

    How to connect flexible conduit to a fitting

    Flexible conduit is connected to a fitting in four steps: choose the fitting, cut the conduit, seat it and tighten the cap, then fix the fitting with its nut. For a sealed run, conduit and fitting must share the same protection class.

  • Guide3 min read

    Galvanized or stainless steel conduit? A comparison

    Galvanized flexible steel conduit works from −50 °C to +300 °C and covers most general installations. Stainless steel conduit works from −100 °C to +600 °C and is made for corrosive environments. The choice comes down to temperature, chemicals and moisture.

  • Guide3 min read

    PVC-coated vs halogen-free (LSZH) conduit

    PVC-coated and halogen-free coated conduits protect the steel core from moisture, oil and dust in the same way; they differ in fire behaviour and temperature. A halogen-free (LSZH) coating gives off little smoke and no halogen gases in a fire, so it is chosen for crowded indoor spaces.

  • Guide3 min read

    Liquid-tight conduit: where and why it is used

    Liquid-tight conduit is galvanized flexible steel conduit enclosed in a thick PVC or halogen-free jacket, rated IP66–IP69. It is used wherever cables meet water, dust, petrol or solvents.

  • Guide4 min read

    How to choose a flexible steel conduit

    Four questions decide the right flexible steel conduit: ambient temperature, exposure to water and dust, electromagnetic interference, and cable size. Temperature picks the material, sealing picks the coating, interference picks the braid, and the cable bundle picks the diameter.