In short
In an IP code the first digit is protection against dust and solid objects, the second against water. IP68 means fully dust-tight and able to withstand continuous immersion.
How to read an IP code
The IP (Ingress Protection) code is defined in IEC 60529 and has two digits. The first is the degree of protection against solid objects and dust, the second against water; the higher the digit, the greater the protection. An X in place of a digit (IPX7, for example) means no rating has been given for that part.
| First digit | Protection against solids and dust |
|---|---|
| 0 | No protection |
| 1 | Objects larger than 50 mm (contact with a hand) |
| 2 | Objects larger than 12.5 mm (a finger) |
| 3 | Objects larger than 2.5 mm (tools, thick wire) |
| 4 | Objects larger than 1 mm (thin wire, screws) |
| 5 | Dust-protected: dust may enter, but not in harmful amounts |
| 6 | Dust-tight |
| Second digit | Protection against water |
|---|---|
| 0 | No protection |
| 1 | Vertically dripping water |
| 2 | Dripping water when tilted by 15° |
| 3 | Spraying water (up to 60°) |
| 4 | Splashing water from any direction |
| 5 | Water jets |
| 6 | Powerful water jets |
| 7 | Temporary immersion (1 m, 30 minutes) |
| 8 | Continuous immersion (under conditions the manufacturer states) |
| 9 | High-pressure, high-temperature water jets |
The ratings people ask about most
- IP54: dust-protected and resistant to splashing water; enough for indoor areas with moisture and oil.
- IP65: dust-tight and resistant to water jets; common for boxes in places that are hosed down or splashed.
- IP66: dust-tight and resistant to powerful water jets.
- IP67: dust-tight; in the standard test it can stay under 1 metre of water for 30 minutes.
- IP68: dust-tight; withstands longer and deeper immersion than IP67, under conditions the manufacturer states.
- IP69: dust-tight; withstands washing with high-pressure hot water.
The difference between IP67 and IP68
Both are dust-tight; the difference is how long and how deep the product can stay under water. For IP67 the standard fixes the test: 1 metre for 30 minutes. For IP68 the conditions are more severe and are stated by the manufacturer, so when comparing two IP68 products, look at the manufacturer's conditions.
Protection against water jets (5 and 6) and against immersion (7 and 8) are separate tests. A product that withstands jets may not withstand immersion, and one that withstands immersion may not withstand powerful jets; that is why some products carry two ratings together, such as IP66/IP68.
What it means across the range
| Product | Protection class |
|---|---|
| Uncoated flexible steel conduits (galvanized, stainless) | IP40 |
| Steel-braided galvanized and stainless conduits | IP40 |
| PVC-jacketed steel-braided conduit | IP54 |
| PVC-coated flexible steel conduit | IP54–IP65 |
| Halogen-free coated flexible steel conduit | IP54–IP66 |
| Liquid-tight steel-braided conduit | IP66 |
| Liquid-tight PVC-jacketed conduit | IP66–IP68 |
| Liquid-tight halogen-free jacketed conduit | IP66–IP69 |
| Polyamide and PVC corrugated conduits | IP66–IP68 |
| Steel conduit fitting | IP54 |
| Liquid-tight fitting, compression (Silok) gland | IP67 |
| Polyamide conduit connectors (with a suitable gasket) | IP67 |
| Metal and polyamide cable glands | IP68 |
| Ex cable glands | IP66–IP68 |
| ABS junction box, Acqua series distribution board | IP65 |
| Sealed mini junction box | IP55 |
A run is only as well protected as its weakest link
An IP68 conduit connected with an IP54 fitting makes an IP54 run. In the same way, an enclosure fitted with an IP68 cable gland cannot be better protected than the enclosure itself. An unused cable entry left open loses the box its protection altogether; spare entries should be closed with blind plugs.
- Define the environment: dust, splashing water, jets, immersion or pressure washing.
- Choose conduit, fittings and boxes of the same class or higher.
- Check that the fitting's seal and O-ring are in place and undamaged.
- Choose the cable gland so that its clamping range takes the cable's outer diameter; a loose gland leaks.
- Close spare entries with blind plugs.
The IP code covers protection against dust and water only. Impact resistance has its own rating, the IK code, and the fire behaviour of plastics is rated with the UL94 classes.
What is the difference between IP65 and IP67?
Both are dust-tight. IP65 withstands water jets but is not tested for immersion; IP67 withstands 30 minutes under 1 metre of water. Where water can collect or the product may be submerged, choose IP67 or IP68.
Is IP54 enough outdoors?
IP54 protects against splashing water, not against direct water jets or pressure washing. It may be enough outdoors under cover, but in the open and where things are washed down, IP65 or higher is preferred.
What does IP20 mean?
IP20 means protected against solid objects larger than 12.5 mm (a finger) and not protected against water; it is for dry indoor areas. Our cable reels are rated IP20; the FLX-MM German-type metal reel also comes with an IP44 option.
Related products

- IP66–IP68

- IP67

- IP68

- IP66–IP68
- LSZH

- IP65
More articles

Guide5 min read
Flexible steel conduit sizes: inch, ID and OD table
Flexible steel conduit is made in 18 sizes from 1/4" to 4" and is chosen by its inner diameter: 1/2" conduit, for example, is 16 mm inside and 20 mm outside. The inch value is a name; conduit, fittings and clamps are matched by their millimetre dimensions.

Guide4 min read
Cable glands explained: what they do and how to choose
A cable gland is the fitting that keeps water and dust out where a cable enters an enclosure or device and anchors the cable against pulling. The right gland is chosen by four things: the cable's outer diameter, the thread type, the thread length and the environment.

Guide4 min read
Polyamide vs PVC corrugated conduit: the difference
Polyamide corrugated conduit works from −40 °C to +120 °C, is halogen-free and self-extinguishing. PVC corrugated conduit works from −20 °C to +70 °C and is made for general-purpose installations. Polyamide is chosen where it is hot, where things move, or where halogen-free material is required.

Guide3 min read
Cable trunking or rigid PVC conduit? Types and sizes
Cable trunking is a profile with an opening cover, practical for surface runs and panel wiring where cables will be added later. Rigid PVC conduit carries cables in a closed tube and is made for surface and concealed installations. The choice depends on how much protection the cable needs and whether it will change.

Guide3 min read
What is EMT conduit? How it differs from other conduit
EMT (electrical metallic tubing) is thin-wall, threadless galvanized steel conduit for electrical installations inside buildings. Its ends are not threaded; it is joined with screw-type or compression couplings and bent to change direction.

Guide3 min read
How to connect flexible conduit to a fitting
Flexible conduit is connected to a fitting in four steps: choose the fitting, cut the conduit, seat it and tighten the cap, then fix the fitting with its nut. For a sealed run, conduit and fitting must share the same protection class.

Guide3 min read
Galvanized or stainless steel conduit? A comparison
Galvanized flexible steel conduit works from −50 °C to +300 °C and covers most general installations. Stainless steel conduit works from −100 °C to +600 °C and is made for corrosive environments. The choice comes down to temperature, chemicals and moisture.

Guide3 min read
PVC-coated vs halogen-free (LSZH) conduit
PVC-coated and halogen-free coated conduits protect the steel core from moisture, oil and dust in the same way; they differ in fire behaviour and temperature. A halogen-free (LSZH) coating gives off little smoke and no halogen gases in a fire, so it is chosen for crowded indoor spaces.

Guide3 min read
Liquid-tight conduit: where and why it is used
Liquid-tight conduit is galvanized flexible steel conduit enclosed in a thick PVC or halogen-free jacket, rated IP66–IP69. It is used wherever cables meet water, dust, petrol or solvents.

Guide4 min read
How to choose a flexible steel conduit
Four questions decide the right flexible steel conduit: ambient temperature, exposure to water and dust, electromagnetic interference, and cable size. Temperature picks the material, sealing picks the coating, interference picks the braid, and the cable bundle picks the diameter.

Technical3 min read
PG vs metric gland threads: the difference and which to choose
PG and metric are two separate thread standards for cable glands, and they do not fit each other. New designs use metric threads; for existing enclosures with PG entries, choose a PG gland or an adapter.